SME Managed

SCE 2007 Fault Finding: OpsMgr Health Service startup problem

image I installed SCE 2007 in my lab today, and as I do with all my Lab Machines had installed Logmein Free so I could show people features or builds when out and about. After all you can only share so much RDP in a NAT'ed Config.

After the install, the configuration wizard launched and over 80% of the config items failed. I checked that all the SCE Services were running and found I could not start the OpsMgr Health Service. A quick Live Search and discovered an Issue with Logmein.

I removed the Logmein Remote Control Tool and all is well with the world again.

The only other thing that I think is worth mentioning is when using the Microsoft Managed News Groups it would be cool if people fed back the Solutions to close the case properly.

 

Was this post useful?
Yes
No
Other:

Comments

SME Managed said:

When I start an install task, I try to gather as many of the required tools and fixes as possible. I

# December 26, 2007 8:12 PM

David Mackie's Blue Brain said:

When I start an install task, I try to gather as many of the required tools and fixes as possible. I

# December 26, 2007 8:12 PM

SME Managed said:

Assuming you conducted the installation I described for SBS 2003 SP1 / R2 the launch of the Essentials

# December 31, 2007 6:33 PM

David Mackie's Blue Brain said:

Assuming you conducted the installation I described for SBS 2003 SP1 / R2 the launch of the Essentials

# December 31, 2007 6:33 PM